The main purpose of good lighting design for the office can benefit various aspects, including improved employee health and well-being, increased productivity, enhanced visual comfort, energy efficiency, and aesthetics, and created office atmosphere.
Lighting design points
Referring to some countries’ office lighting standards, the reference of office lx range is 200lx ~ 750lx, there are different lx requirements for each functional area.
Does high illumination equal high vision?
High illumination is not equal to high vision. Too high illumination will increase eye fatigue, damage our health, and waste resources. So our first design point is to keep office lighting comfortable, satisfying the illumination to create soft and no glare so that the workers are not easily fatigued for a long time.
What is the lighting quality evaluation index?
UGR
Unified glare rating is a quantitative index used to evaluate the uncomfortable glare of indoor lighting. It measures the psychological amount of the subjective reaction of discomfort caused by the light emitted by the lighting device in the visual environment to the human eye.
There are totally 7 index : 28、25、22、19、16、13、10
According to the standard sheet, the conventional definition is the lowest energy consumption, heat output, and maintenance requirement.
Ra
What about the general color rendering index
The color rendering of the light source refers to the degree to which the light source presents the natural primary color of the object.
The International Commission on Illumination (CIE) defines the color rendering index of sunlight as 100 and specifies 15 test colors, with R1-R15 representing the display index of these 15 colors respectively. When comparing a light source with a specified reference light source, an index value of 100 is the best.
Among them, R9 is an indicator for evaluating the quality of red reproduction, and the values of the three types of light sources vary greatly. Since the display index of the LED light source is very low or even negative, the meat and the plate look dim.
CCT
CCT is smaller than 3300K that suitable for guest rooms, bedrooms, inpatient wards, and pubs, and the CCT between 3300 ~ 5300 is suited for offices, classrooms, reading rooms, supermarkets, consulting rooms, laboratories, operating rooms, etc. Then CCT larger than 5300k is suited for hot working shops, and places with high illumination. Generally, most offices applied 4000k CCT lighting during their work.
Light fixture placement
There are several types of office light fixture placement
LPD index has a deep relationship with light source, choice of light fixture, and the placement of light fixtures.
- LPD index corresponding with illumination value.
- There is trouble when LPD exceeds the standard.
Direct lighting design + indirect lighting design:
This design solution is suitable for personal offices, meeting rooms, and staircases, which can provide soft reflecting lighting and direct lighting light on the object surface.
The three types of offices, also have some different lighting designs, such as panel lights and ceiling lights are suitable for general office ceiling lighting, while personal offices prefer to apply pendant lights and track lights. In the office staircase, generally applied wall light, wall wash light, and downlight.
Other tips
It is necessary to consider the actual demand before installing the light fixtures, including furniture placement, shape of smallpox, airconditioner, fire main, etc.
Continuous light strip: Those lamps are connected with special connectors, and there is only a small shadow
Combined light strip: Different connectors are used to connect lamps with each other in different