The rapid development of LED industry not only leads to the rapid improvement of LED luminous efficiency, but also makes the utilization rate of LED universal to every family. Because LED lamps are more likely to cause dazzle problems, the quality requirements of LED lamps will be higher.
# What is the Unified Glare Rating?
Firstly, Glare is a visual sensation caused by excessive and uncontrolled brightness. In simpler words, UGR predicts the amount of discomfortcausing glare produced by a lighting installation for a fixed set of conditions. Discomfort glare can result in annoyance, headaches or eyestrain.
Glare can be divided into two categories based on the visual impact on the human eye: disabling glare and uncomfortable glare. For different lighting environments, not only the glare evaluation methods are different, but also the evaluation standards are different at home and abroad.
Domestic and international standards for glare testing:
|
Domestic Standards |
Foreign Standards |
|
Outdoor Lighting |
Roadway lighting |
CJJ45-2006
|
EN13201 CIE140-2000 |
Tunnel lighting |
JTJ026.1-1999 |
CIE88-2004 |
|
Outdoor stadium lighting |
JGJ153-2007 |
CIE112-1994 EN12193 EN12464-2 |
|
Indoor Lighting |
Indoor lighting |
GB50034-2013 |
CIE117-1995 CIE146/147-2002 |
Indoor daylighting |
GB50033-2013 |
BS8206-2:2008 |
|
Indoor stadium lighting |
JGJ153-2007
|
EN12193 EN12464-1 |
# What is a reasonable index for UGR
Studies have found that people who live and work in light polluted environment for a long time will suffer different degrees of damage to the retina and iris, and their vision will decline sharply. The incidence of cataract is as high as 45%. Over 60% of high school students in china are myopic, partly due to the habit of using their eyes, but also due to the pollution of the visual environment.
Different UGR corresponds to different sensitivities
UGR |
Sense of value |
28 |
Intolerable value |
25 |
Uncomfortable value |
22 |
Just uncomfortable value |
19 |
Comfort and discomfort threshold value |
16 |
Just comfort value |
13 |
Just felt the value of the glare |
10 |
No glare sensitivities |
In conclusion, UGR should be less than 19 index is better.
So 19 is the critical value of the glare index. When the value exceeds the estimated value, it can be determined that the design structure of the lamp is unreasonable. The smaller the glare value is, the smaller the glare harm is. however, there are only a small handful of UGR<19 linear luminaires available at present that provide the continuous “stripe of light” visual effect desired and are reasonably priced.Many of them have a low lumen output and provide poor uniformity which means more luminaires are needed to light the space and cost are driven up.
#About our company’s products
The glare value of the the lamps developed by our company is within the range of reasonable eye care, and without losing aesthetic felling. Various lamps are suitable for various occasions. For example:
1、AL08