Code |
XSI-9W205-A4DA0F |
XSI-22W550-A8DA0F |
XSI-45W1050-A8DA0F |
XSI-60W1500-A8DA0F |
Input |
Input Power |
4-9W |
8-22W |
24-45W |
45-60W |
Input Voltage |
180-265V |
Rated Input Voltage(V) |
200-240V |
Frequency |
50/60HZ |
Input Current |
≤0.05A |
≤0.14A |
≤0.28A |
≤0.37A |
Rated Input Current |
≤0.04A |
≤0.13A |
≤0.25A |
≤0.34A |
Power Factor (typ) |
0.9 |
Total Harmonic |
<20% @230V |
Distortion(THD) |
Efficiency (typ) |
≥78% |
≥86% |
≥88% |
≥90% |
Inrush Current (Typ.) |
18.8A/34.8uS |
15.1A/113uS |
16A/214uS |
24.2A/326uS |
Max Circuit Breaker |
Please refer to" Circuit breaker Specification" |
Leakage Current |
<0.5mA/240V |
No Load Wattage |
<0.5W @230V |
Output |
Output Voltage Range |
30-40V |
Rated Output Current |
100-205mA |
200-550mA |
600-1050mA |
1050-1500mA |
Line Regulation |
±5% |
Open Circuit Voltage (max) |
50V |
Setup time(note1) |
<1S @230V |
Flickering Index(IEEEStd 1789) |
3%(NO RISK) |
6%(NO RISK) |
6%(NO RISK) |
Protection |
Short Circuit Protection |
Constant current limiting, recovers automatically after fault condition is removed |
Over Voltage Protection |
Shut down o/p voltage |
Over Temperature Protection |
Shut down o/p voltage, recovers automatically after temperature goes down |
Safety &EMC |
Safety Standards |
IEC/EN61347-1, IEC/EN61347-2-13, IEC/EN62384 independent,GB19510.14,GB19510.1 approved |
Withstand Voltage |
I/P-O/P:3.75KVac,<5mA 60S; I/P-FG:1.6KVac,<5mA 60S; O/P-FG:0.5KVac,<5mA 60S |
Isolation Resistance |
I/P-O/P: 500VDC, ≥100M Ω |
Surge |
IEC/EN61000-4-5(L-N:0.5KV, ) |
IEC/EN61000-4-5(L-N:1KV, ) |
EMC Emission |
IEC/EN55015, IEC/EN61000-3-2 |
EMC Immunity |
IEC/EN61000-4-2,3,4,5,6,8,11; IEC/EN61547 |
Other |
Dimension(L*W*H) |
131.0*50.0*26.0mm |
143.0*58.0*30.0mm |
144.0*80.0*32.0mm |
156.0*80.0*32.0mm |
Weight |
0.09Kg |
0.13Kg |
0.20Kg |
0.25Kg |